2BV5 Series Single-Stage Liquid Ring Vacuum Pump
Summarize
2BV, 2BV2 single-stage liquid ring vacuum pump is horizontal direct connection type. The whole pump is composed of intake and exhaust air pump cover, intake and exhaust disc, pump body, mechanical seal and blade. This series of vacuum pump has the advantages of compact structure, convenient installation and maintenance, and is mainly suitable for vacuum filling, vacuum sterilization, vacuum forming, vacuum concentration and other processes.
2BV Type 2BV2 Series Single-Stage Liquid Ring Vacuum Pump
Summarize
2BV, 2BV2 single-stage liquid ring vacuum pump is horizontal direct connection type. The whole pump is composed of intake and exhaust air pump cover, intake and exhaust disc, pump body, mechanical seal and blade. This series of vacuum pump has the advantages of compact structure, convenient installation and maintenance, and is mainly suitable for vacuum filling, vacuum sterilization, vacuum forming, vacuum concentration and other processes.
Type-Performance-parameter
Performance parameters | Pumping Speed (m3/min) | Pressure Limit (Pa) | Power of Motor (KW) | Revolution (rpm) | liquid-supply quantity (L/min) | Caliber of Inlet & outlet (mm) |
2BV2060 | 0.45 | 3300 | 1.1 | 2840 | 2 | 62 |
2BV2061 | 0.86 | 3300 | 1.5 | 2840 | 2 | 65 |
2BV2070 | 1.33 | 3300 | 3 | 2860 | 2.5 | 66 |
2BV2071 | 1.83 | 3300 | 4 | 2880 | 4.2 | 72 |
2BV5110 | 2.75 | 3300 | 4 | 1450 | 6.7 | 50 |
2BV5111 | 3.83 | 3300 | 5.5 | 1450 | 8.3 | 50 |
2BV5121 | 4.66 | 3300 | 7.5 | 1450 | 10 | 65 |
2BV5131 | 6.66 | 3300 | 11 | 1430 | 15 | 65 |
2BV5161 | 8.33 | 3300 | 15 | 970 | 20 | 80 |
2BV6110 | 2.75 | 3300 | 4 | 1450 | 6.7 | 50 |
2BV6111 | 3.83 | 3300 | 5.5 | 1450 | 8.3 | 50 |
2BV6121 | 4.66 | 3300 | 7.5 | 1450 | 10 | 65 |
2BV6131 | 6.66 | 3300 | 11 | 1430 | 15 | 65 |
2BV6161 | 8.33 | 3300 | 15 | 970 | 20 | 80 |
Note:
1. The performance indicators listed in the table are obtained under the following conditions: ①Atmospheric pressure 760mmHg;②liquid temperature 15℃; ③Air temperature 20℃; ④relative humidity of gas 70%;
2. The liquid supply is the value when the suction vacuum is -400mmHg, which can be greater than this value when the limit vacuum is used.
3. The deviation of pumping volume shall not exceed ±3%.
4. The above vacuum pump can be supplied with all stainless steel.